Specification sheet
Grade A 48×40 GMA, specified down to the nail.

Order to this specification
Quote 'Grade A spec sheet' in the message and the order will be graded against exactly this document.
- Written quotes, usually inside one business day
- Loads from 100 pallets to full 53' trailers
- We buy as readily as we sell — tell us which way it flows

Intake
Mixed cores straight off a collection run. Every one of these gets a grader's four-way decision before it goes anywhere.
Dimensions and members
The build.
| Element | Specification | Tolerance | Reject if |
|---|---|---|---|
| Overall footprint | 48″ × 40″ | ± ½″ | More than ½″ under on either axis |
| Overall height | 5½″ nominal | ± ¼″ | Over 5¾″ — jams automated handling |
| Top deck boards | 7, full length, 3½″ – 5½″ wide | — | Any board short, split or replaced with a splice |
| Top deck thickness | 9/16″ nominal hardwood | ± 1/16″ | Under ½″ on any board |
| Bottom deck boards | 3, full length | — | Missing or split through |
| Stringers | 3, 1⅜″ × 3½″ × 48″ hardwood | — | Any crack, plug or repair |
| Fork openings | Four-way notched, 9″ × 1½″ notch | ± ¼″ | Notch broken through to the bottom deck |
| Squareness | Diagonals equal | ± ¼″ | Out of square by more than ¼″ |
| Fasteners | Helically threaded or stiff-stock nails | — | Protruding above deck surface |
| Moisture content | Under 19% | — | Reading above 19% at any of three points |
Performance
What it will actually carry.
6,000 lb
Static load
Sitting on a flat floor, evenly distributed.
3,000 lb
Dynamic load
Being moved by a forklift or jack.
2,100 lb
Racked load
Unsupported across the rack beams, edge-supported.
45–55 lb
Unit weight
Mixed hardwood, at dispatch moisture.
Species group
What Grade A does not mean
Rejection
What we pull off the line.
Any repair to a stringer
A companion stringer is a legitimate repair and produces a perfectly serviceable pallet — but not a Grade A one. Companion- repaired units grade B. This is stricter than much of the industry and it is deliberate: racked loads are where stringer repairs get tested.
Spliced or short deck boards
A deck board shorter than the full 40 inches, or two boards butted to make up a run, fails Grade A regardless of how tidily it was done. See repair standards.
Moisture above 19%
Damp wood loses stiffness, gains weight, and will grow mould under wrap within days. Units above 19% are held for drying or regraded, never shipped as A.
Odour, staining or residue
Chemical smell, oil staining, or visible residue takes a unit out of the food and pharmaceutical stream entirely and usually out of Grade A. See food and beverage handling.
Protruding fasteners
Any nail standing proud of the deck surface. It is a product damage claim waiting to happen and it takes ten seconds to fix at the cleaning station.